I have a ce5.0 image that gets downloaded to the device over ethernet and
booted properly. I can see the processes, threads etc. in my target control
window (gi proc etc.). But non of my remote tools can't connect to it. I
receive an error message "Platform Manager was unable to download files to
the device. Please check your startup server and tranport settings and try
again". I have tried different tranport settings (kitl and TCP/IP) with no
luck.
Can someone show some light here?
Thanks.

Re: Romote tools refuse to connect by Javier

Javier
Thu May 18 02:53:33 CDT 2006

What start up server are you using?
I use active sync over USB and it works perfect.
Regards
Javier

On Tue, 16 May 2006 20:28:02 +0200, Kap <Kap@discussions.microsoft.com> =
=

wrote:

> I have a ce5.0 image that gets downloaded to the device over ethernet =
and
> booted properly. I can see the processes, threads etc. in my target =

> control
> window (gi proc etc.). But non of my remote tools can't connect to it.=
I
> receive an error message "Platform Manager was unable to download file=
s =

> to
> the device. Please check your startup server and tranport settings and=
=

> try
> again". I have tried different tranport settings (kitl and TCP/IP) wit=
h =

> no
> luck.
> Can someone show some light here?
> Thanks.



-- =

Javier Grijalba
www.positivesystems.com
Touch Panel - PC Systems

Re: Romote tools refuse to connect by Kap

Kap
Thu May 18 15:04:02 CDT 2006

Well, I have tried different servers with no luck. The following is the debug
output I get when I try to connect a remote tool.

3551409 PID:41ab7a3e TID:41bb0eee Opening KITL stream "platmanXport"...
3551412 PID:41ab7a3e TID:41bb0eee KITL stream platmanXport: buffer
start=0x44800000 end=0x44806400
3551461 PID:41ab7a3e TID:41bb0eee CKITLConnection established for stream
platmanXport
3551463 PID:41ab7a3e TID:41bb0eee CKITLConnection::Close stream platmanXport
3551465 PID:41ab7a3e TID:41bb0eee Opening KITL stream "strm-9"...
3551467 PID:41ab7a3e TID:41bb0eee KITL stream strm-9: buffer
start=0x44800000 end=0x44806400
3551662 PID:41ab7a3e TID:41bb0eee CKITLConnection established for stream
strm-9
3551911 PID:41ab7a3e TID:41bb0eee Opening KITL stream "platmanXport"...
3551913 PID:41ab7a3e TID:41bb0eee KITL stream platmanXport: buffer
start=0x44900000 end=0x44906400
3552113 PID:41ab7a3e TID:41bb0eee CKITLConnection established for stream
platmanXport
3552115 PID:41ab7a3e TID:41bb0eee CKITLConnection::Close stream platmanXport
3552117 PID:41ab7a3e TID:41bb0eee Opening KITL stream "strm-10"...
3552120 PID:41ab7a3e TID:41bb0eee KITL stream strm-10: buffer
start=0x44900000 end=0x44906400
3552314 PID:41ab7a3e TID:41bb0eee CKITLConnection established for stream
strm-10
3552317 PID:41ab7a3e TID:41bb0eee Checking if extended keep alive timeouts
feature is set...No
3553464 PID:41ab7a3e TID:41bb0eee CKITLConnection::Close stream strm-9
3553466 PID:41ab7a3e TID:41bb0eee CKITLConnection::Close stream strm-10

Any Ideas?

Thanks,
Kap

"Javier Grijalba" wrote:

> What start up server are you using?
> I use active sync over USB and it works perfect.
> Regards
> Javier
>
> On Tue, 16 May 2006 20:28:02 +0200, Kap <Kap@discussions.microsoft.com>
> wrote:
>
> > I have a ce5.0 image that gets downloaded to the device over ethernet and
> > booted properly. I can see the processes, threads etc. in my target
> > control
> > window (gi proc etc.). But non of my remote tools can't connect to it. I
> > receive an error message "Platform Manager was unable to download files
> > to
> > the device. Please check your startup server and tranport settings and
> > try
> > again". I have tried different tranport settings (kitl and TCP/IP) with
> > no
> > luck.
> > Can someone show some light here?
> > Thanks.
>
>
>
> --
> Javier Grijalba
> www.positivesystems.com
> Touch Panel - PC Systems
>