I have a Dell Optiplex GX110 system that I have installed
a ActionTec PC750 PCMCIA reader in. Under Windows 2000,
the PC750 has no problems, but I can't get it to work if I
run CE .NET on this system. I have built my CEPC using the
Standard WebPad configuration and have selected the TI1250
driver for PCMCIA. The ActionTec device is actually using
a TI1225 controller but I think they are compatible as
other people have reported that they have gotten the PC750
to work in their CEPC. Below is the error log I get when
the driver is started.
4294770801 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcibus.dll at address 0x01310000-0x01323000
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCIBUS.DLL'
4294770838 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: WARNING: No matching registry key was
found for placed device 0/0/0.
4294770838 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: Problems can result if the
device is being used while configuring PCIbus.
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt:(Bus=0,Device=1,Pin=1)
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=31 SlotNumber=0
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=0,INTA_IrqBitMap=0
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=30 SlotNumber=0
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770839 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770840 PID:e3fc3642 TID:e3e75f6e 0x83e72800: OR: No
protseqs configured
4294770840 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=62,INTC_IrqBitMap=def8
4294770842 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770842 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=1 SlotNumber=0
4294770842 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770842 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=0,INTB_IrqBitMap=0
4294770842 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770842 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=0,INTC_IrqBitMap=0
4294770843 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: -
OEMGetInterrupt:Find existing IRQ return IRQ=9
4294770845 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: WARNING: No matching registry key was
found for placed device 1/7/0.
4294770845 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: Problems can result if the
device is being used while configuring PCIbus.
4294770848 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
DeviceConfig+(0)
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc+(Bus 1, Device 10, Function 0)
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc: BAR(1/10/0): Offset 0x10, Type Memory, Size
0x1000
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc: BAR(1/10/0): Offset 0xffffffff, Type Memory,
Size 0x10000
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc: BAR(1/10/0): Offset 0xfffffffe, Type IO, Size
0x4000
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc-
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt:(Bus=1,Device=10,Pin=1)
4294770875 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=31 SlotNumber=0
4294770876 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=0,INTA_IrqBitMap=0
4294770876 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770876 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294770876 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770876 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=30 SlotNumber=0
4294770877 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770877 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770877 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=62,INTC_IrqBitMap=def8
4294770877 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770877 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=1 SlotNumber=0
4294770877 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770879 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=0,INTB_IrqBitMap=0
4294770879 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770879 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=0,INTC_IrqBitMap=0
4294770879 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=12 SlotNumber=0
4294770879 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=62,INTA_IrqBitMap=def8
4294770879 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=0,INTB_IrqBitMap=0
4294770880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=0,INTC_IrqBitMap=0
4294770880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=7 SlotNumber=1
4294770880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=62,INTC_IrqBitMap=def8
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=8 SlotNumber=2
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=61,INTA_IrqBitMap=def8
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=62,INTB_IrqBitMap=def8
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=63,INTC_IrqBitMap=def8
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=60,INTC_IrqBitMap=def8
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=9 SlotNumber=3
4294770881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=62,INTA_IrqBitMap=def8
4294770882 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=63,INTB_IrqBitMap=def8
4294770882 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=60,INTC_IrqBitMap=def8
4294770882 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=61,INTC_IrqBitMap=def8
4294770882 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=10 SlotNumber=4
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=63,INTA_IrqBitMap=def8
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=60,INTB_IrqBitMap=def8
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=61,INTC_IrqBitMap=def8
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=62,INTC_IrqBitMap=def8
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(15) to this device
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=f01)
4294770883 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770884 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(14) to this device
4294770884 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=e01)
4294770884 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770884 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(12) to this device
4294770884 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=c01)
4294770884 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770885 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(11) to this device
4294770885 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=b01)
4294770885 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770885 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(7) to this device
4294770885 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=701)
4294770886 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770886 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(6) to this device
4294770886 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=601)
4294770886 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770886 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(4) to this device
4294770886 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=401)
4294770887 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770887 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: Mapping New IRQ(3) to this device
4294770887 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: BiosMapIqr
(EAX=b10f,EBX=150,ECX=301)
4294770887 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
BiosMapIqr return 0 and EAX=880f
4294770887 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCardBusBridge: Get IRQ call failed.
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
DeviceConfig+(0)
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc+(Bus 1, Device 10, Function 1)
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
ConfigRsrc: BAR(1/10/1): Offset 0x10, Type Memory, Size
0x1000
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x8
fc3000: PCMCIA!
ConfigRsrc-
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt:(Bus=1,Device=10,Pin=2)
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=31 SlotNumber=0
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=0,INTA_IrqBitMap=0
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770888 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=30 SlotNumber=0
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=62,INTC_IrqBitMap=def8
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770889 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=0 ,Device=1 SlotNumber=0
4294770890 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770890 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=0,INTB_IrqBitMap=0
4294770890 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770890 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=0,INTC_IrqBitMap=0
4294770890 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=12 SlotNumber=0
4294770891 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=62,INTA_IrqBitMap=def8
4294770891 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=0,INTB_IrqBitMap=0
4294770891 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=0,INTC_IrqBitMap=0
4294770891 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=0,INTC_IrqBitMap=0
4294770891 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=7 SlotNumber=1
4294770891 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=60,INTA_IrqBitMap=def8
4294770892 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=61,INTB_IrqBitMap=def8
4294770892 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=62,INTC_IrqBitMap=def8
4294770892 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=63,INTC_IrqBitMap=def8
4294770892 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=8 SlotNumber=2
4294770892 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=61,INTA_IrqBitMap=def8
4294770892 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=62,INTB_IrqBitMap=def8
4294770893 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=63,INTC_IrqBitMap=def8
4294770893 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=60,INTC_IrqBitMap=def8
4294770893 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=9 SlotNumber=3
4294770893 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=62,INTA_IrqBitMap=def8
4294770893 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=63,INTB_IrqBitMap=def8
4294770893 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=60,INTC_IrqBitMap=def8
4294770894 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=61,INTC_IrqBitMap=def8
4294770894 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
OEMGetInterrupt: for Bus=1 ,Device=10 SlotNumber=4
4294770894 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTA_LinkValue=63,INTA_IrqBitMap=def8
4294770894 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTB_LinkValue=60,INTB_IrqBitMap=def8
4294770894 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTC_LinkValue=61,INTC_IrqBitMap=def8
4294770894 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
INTD_LinkValue=62,INTC_IrqBitMap=def8
4294770895 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: -
OEMGetInterrupt:Find existing IRQ return IRQ=9
4294770897 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: WARNING: No matching registry key was
found for placed device 0/31/0.
4294770897 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: Problems can result if the
device is being used while configuring PCIbus.
4294770897 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: WARNING: No matching registry key was
found for placed device 0/31/1.
4294770897 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: Problems can result if the
device is being used while configuring PCIbus.
4294770898 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: WARNING: No matching registry key was
found for placed device 0/31/2.
4294770898 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: Problems can result if the
device is being used while configuring PCIbus.
4294770898 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: WARNING: No matching registry key was
found for placed device 0/31/3.
4294770898 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgCheckBARs: Problems can result if the
device is being used while configuring PCIbus.
4294770899 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgAllocMemSpace: Failed to place Bridge resource: Bus
0, Device 30, Function 0
4294770899 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCIBUS!
PCICfgAllocIoSpace: Failed to place Device resource: Bus
1, Device 10, Function 0
4294770899 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294770899 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
4294770914 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294770961 PID:e3fc3642 TID:e3f54f72 0x83f3b9a8:
IPTimer: setting IPTimer of NTE 160150 to 0
4294772383 PID:e3fc3642 TID:e3f54f72 0x83f3b9a8:
*IPTimeout: NOT restarting IPTimeout Timer for NTE
160150
4294772402 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772402 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
DeviceConfig+(2)
4294772402 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294772402 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772405 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
4294772432 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
4294772432 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
DeviceConfig+(3)
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772432 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294772432 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772437 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
4294772465 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772465 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
DeviceConfig+(2)
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772465 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294772465 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
4294772467 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772495 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
4294772495 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: PCMCIA!
DeviceConfig+(3)
4294772495 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294772495 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
4294772820 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: DEVICE!
ActivateDeviceEx(Drivers\BuiltIn\PCI\Instance) entered
4294772820 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: DEVICE!
ActivateDeviceEx(Drivers\BuiltIn\PCI\Instance\PCMCIA2)
entered
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772821 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
4294772848 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772849 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA:InitCardSvc PDCardInitServices returned 25
4294772849 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294772849 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
Loaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772850 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: DEVICE!
StartOneDriver RegisterDevice(<nil>, 0, pcmcia.dll,
0x802d8d8) failed
4294772850 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: DEVICE!
ActivateDeviceEx(Drivers\BuiltIn\PCI\Instance\PCMCIA1)
entered
4294772852 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: >>>
Loading module pcmcia.dll at address 0x01290000-0x012B3000
4294772880 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_ATTACH
Unloaded symbols for 'C:\WINCE420
\PUBLIC\MYCEPCWEBPAD\RELDIR\CEPC_X86DEBUG\PCMCIA.DLL'
4294772881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA:InitCardSvc PDCardInitServices returned 1
4294772881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000:
PCMCIA.DLL DLL_PROCESS_DETACH
4294772881 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: <<<
Unloading module pcmcia.dll at address 0x01290000-
0x012B3000
4294772882 PID:e3fc3642 TID:e3fd2fb2 0x83fc3000: DEVICE!
StartOneDriver RegisterDevice(<nil>, 0, pcmcia.dll,
0x802d8d8) failed
Does anyone know what might be going wrong here?
Thanks in advance for any help,
Brian